CM550-52X

General-purpose cellular RTU

Integrated analog and digital acquisition, remote control and cellular communications for distributed monitoring installations. Interface and radio configuration must be matched to the selected variant.

RS232
1 port; 110–115200 bit/s
RS485
1 port
Acquisition functions
Analog inputs, digital inputs/outputs and pulse counting; confirm channel configuration
Digital acquisition and control
8 digital inputs, 2 PWM outputs and 4 relay outputs listed; confirm signal levels and ordered hardware
CM550-52X original product photograph, view 1

Product photography. Open full image ↗

Product overview

  • Analog and digital signal acquisition
  • RS232 and RS485 interfaces
  • Pulse counting

Technical specifications

Options vary by model, hardware revision and firmware.

Key specifications

CM550-52X product specifications
RS2321 port; 110–115200 bit/s
RS4851 port
Acquisition functionsAnalog inputs, digital inputs/outputs and pulse counting; confirm channel configuration
Digital acquisition and control8 digital inputs, 2 PWM outputs and 4 relay outputs listed; confirm signal levels and ordered hardware
Cellular variants4G full-network and 4G Cat.1 variants listed; confirm regional module
EthernetConfirmation required — table states one port but also references LAN1–LAN4
Positioning / wireless sensor modulesGPS / BeiDou and Zigbee described as options; confirm model applicability
Modbus / MQTT / SCADAConfirmation required — target protocol, firmware and interoperability require technical review
5G availabilityConfirmation required — navigation mentions 5G; selection guide lists 4G variants

Source model selection

CM550-52 Series — Industrial remote terminal unit · Source revision not stated · Source p. 1

CM550-52X — Source model selection
CM550-52FInterfaces: Terminals / Ethernet; Network: Seven-mode cellular; RS232: Yes; RS485: Yes; Buffer: 256 Mbit
CM550-52TInterfaces: Terminals / Ethernet; Network: 4G/GPRS/GSM; RS232: Yes; RS485: Yes; Buffer: 256 Mbit

Ports and electrical limits

CM550-52 Series — Industrial remote terminal unit · Source revision not stated · Source p. 4

CM550-52X — Ports and electrical limits
RS232One port; source 15 kV ESD protection; 5/6/7/8 data bits; 1/1.5/2 stop bits; none/even/odd/SPACE/MARK parity; 110-115200 bit/s.
RS485One port with source 15 kV ESD protection.
EthernetOne 10/100 Base-T port, source parenthesis Lan1-lan4; IEEE 802-3 / 802-2 notation; 1.5 kV isolation. Port-count wording Confirmation required.
USBOne USB interface.
IndicatorsPOWER, ACT and Online.
AntennaSMA female, 50 ohm; optional 3/5/10/15 m extension cables.
UIM/SIM1.8/3/5 V push-type card interface; 15 kV ESD protection.
PowerTerminal input with reverse-polarity and overcurrent protection.
Analog input16-bit resolution; -10 to +10 V voltage or 0-20 mA current; source accuracy better than ±0.5%, reference basis not stated. Number of channels not specified here.
Digital input0-3.3 V low; 5-30 V high. Eight inputs in feature list, including six counting inputs at 0-1 kHz.
Relay dry contactsFour relays in feature list; source drive capacity 5 A / 30 V DC or 5 A / 250 V AC. Load category/contact life not specified.
Optoisolated digital outputOpen collector; source maxima 30 V, 40 mA and 125 mW. Channel count not specified; combined ratings require confirmation.
Optoisolated PWMTwo outputs in feature list; open collector; source maxima 30 V, 40 mA, 125 mW; 0-1 kHz frequency, adjustable duty cycle. Electrical/frequency conditions Confirmation required.

Radio parameters

CM550-52 Series — Industrial remote terminal unit · Source revision not stated · Source p. 5

CM550-52X — Radio parameters
Wireless moduleIndustrial wireless module; actual modem/configuration must be confirmed.
TDD radio groupLTE TDD 2600/2300 MHz; UMTS 2100/900 MHz; GSM 850/900/1800/1900 MHz; receive diversity UMTS 2100/900 MHz.
FDD radio groupLTE FDD 2600/2100/1800/DD800 MHz (source notation retained); UMTS 2100/900 MHz; receive diversity UMTS 2100/900 MHz.
Source encoding/mode listLTE/UMTS/HSPA+/HSDPA/HSUPA/WCDMA/EDGE/GSM.
TDD-group data ratesLTE TDD DL 68 Mbit/s / UL 17 Mbit/s; DC-HSPA+ DL 42 Mbit/s (category 24); HSPA+ DL 28 Mbit/s (category 18); HSDPA DL 14.4 Mbit/s (category 8); HSUPA+ 5.76 Mbit/s (category 6; source labels DL, direction Confirmation required); WCDMA CS UL/DL 64 kbit/s; WCDMA PS UL/DL 384 kbit/s.
FDD-group data ratesLTE FDD DL 100 Mbit/s / UL 50 Mbit/s; DC-HSPA+ DL 42 Mbit/s (category 24); HSPA+ DL 28 Mbit/s (category 18); HSDPA DL 14.4 Mbit/s (category 8); HSUPA+ 5.76 Mbit/s (category 6; source labels DL, direction Confirmation required); WCDMA CS UL/DL 64 kbit/s; WCDMA PS UL/DL 384 kbit/s.
Transmit powerLTE 23 dBm; WCDMA/HSDPA 24 dBm.
Receive sensitivity<-109 dBm.
servicesData, voice, SMS and fax; verify service support on the ordered modem and regional network.

Hardware and power

CM550-52 Series — Industrial remote terminal unit · Source revision not stated · Source p. 6

CM550-52X — Hardware and power
CPU / MMUIndustrial CPU with MMU memory management.
Flash / SDRAM64 Mbit / 256 Mbit.
Input7-32 V DC in power table; 6-32 V in feature section. Confirm approved input.
Adapter9 V DC / 1.5 A
Communication current0.2 A at 9 V DC
Registration peak1.0 A at 9 V DC
Standby0.15 A at 9 V DC

Mechanical / environment

CM550-52 Series — Industrial remote terminal unit · Source revision not stated · Source p. 6

CM550-52X — Mechanical / environment
HousingMetal, isolated enclosure/system, lightning/EMI design; IP30 .
Body167 x 104 x 26 mm excluding antennas/mounting.
Package350 x 215 x 88 mm
Weight0.52 kg
Operating-25 to +70 °C
Storage-40 to +85 °C
Humidity95% RH, non-condensing.

System connectivity

From field equipment to your system.

See how CM550-52X fits into your installation.

CM550-52X example data flowField equipment: Connected equipment. Serial equipment; Serial link; Field sensors; Analog acquisition Next connection: Device data. Data acquisition: CM550-52X. Next connection: Cellular network. Your system: Customer platform. Monitoring system or data server01 / FIELD EQUIPMENTConnected equipmentSerial equipmentSerial linkField sensorsAnalog acquisitionDevice data02 / DATA ACQUISITIONCM550-52XCM550-52X product photographCellular network03 / YOUR SYSTEMCustomer platformMonitoring system or data serverCM550-52X example data flowField equipment: Connected equipment. Serial equipment; Serial link; Field sensors; Analog acquisition Next connection: Device data. Data acquisition: CM550-52X. Next connection: Cellular network. Your system: Customer platform. Monitoring system or data server01 / FIELD EQUIPMENTConnected equipmentSerial equipmentSerial linkField sensorsAnalog acquisitionDevice data02 / DATA ACQUISITIONCM550-52XCM550-52X product photographCellular network03 / YOUR SYSTEMCustomer platformMonitoring system or data server

Illustrative connection architecture. External equipment and customer software are shown for context. Interfaces and options vary by configuration.

Typical applications

  • Pump station telemetry
  • Water metering integration
  • Wastewater sensor data acquisition
  • Distributed environmental monitoring

Downloads

CM550-52 Series — Industrial remote terminal unit

Source revision not stated · Technical review edition · PDF

Download PDF

Common questions

Is a 5G configuration confirmed?

Confirmation required. The official navigation mentions 4G/5G, while the reviewed selection guide lists 4G models. Request the current ordering guide.

Can it connect directly to our SCADA system?

The manufacturer describes configuration-software integration. Exact protocols, drivers, data mapping and compatibility with your SCADA system require confirmation and testing.

Discuss your project

Complete your project details, then select Email our team to open your email app. Review and send your inquiry there.

Interface, connectivity and customization requirements (optional)