CM550-55X

Industrial remote monitoring RTU

An industrial RTU with serial communications, analog inputs and digital control interfaces. The source specification lists 16-bit analog conversion and a wide DC power input.

Serial interface
1 × RS232; 110–115200 bit/s
Analog input
16-bit conversion; −10 to +10 V or 0–20 mA input
DC input
7–32 V DC
Operating temperature
−25 to +70 °C
CM550-55X original product photograph, view 1

Product photography. Open full image ↗

Technical specifications

Options vary by model, hardware revision and firmware.

Key specifications

CM550-55X product specifications
Serial interface1 × RS232; 110–115200 bit/s
Analog input16-bit conversion; −10 to +10 V or 0–20 mA input
DC input7–32 V DC
Operating temperature−25 to +70 °C

Source model selection

CM550-55 Series — Industrial RTU with GPS/BeiDou positioning · Source revision not stated · Source p. 1

CM550-55X — Source model selection
CM550-55FInterfaces: Terminals / Ethernet; Network: Seven-mode cellular; RS232: Yes; RS485: Yes; Buffer: 256 Mbit
CM550-55TInterfaces: Terminals / Ethernet; Network: 4G/GPRS/GSM; RS232: Yes; RS485: Yes; Buffer: 256 Mbit

Ports and electrical limits

CM550-55 Series — Industrial RTU with GPS/BeiDou positioning · Source revision not stated · Source p. 4

CM550-55X — Ports and electrical limits
RS232One port; source 15 kV ESD protection; 5/6/7/8 data bits; 1/1.5/2 stop bits; none/even/odd/SPACE/MARK parity; 110-115200 bit/s.
RS485One port with source 15 kV ESD protection.
EthernetOne 10/100 Base-T port, source parenthesis Lan1-lan4; IEEE 802-3 / 802-2 notation; 1.5 kV isolation. Port-count wording Confirmation required.
USBOne USB interface.
IndicatorsPOWER, ACT and Online.
AntennaSMA female, 50 ohm; optional 3/5/10/15 m extension cables.
UIM/SIM1.8/3/5 V push-type card interface; 15 kV ESD protection.
PowerTerminal input with reverse-polarity and overcurrent protection.
Analog input16-bit resolution; -10 to +10 V voltage or 0-20 mA current; source accuracy better than ±0.5%, reference basis not stated. Number of channels not specified here.
Digital input0-3.3 V low; 5-30 V high. Eight inputs in feature list, including six counting inputs at 0-1 kHz.
Relay dry contactsFour relays in feature list; source drive capacity 5 A / 30 V DC or 5 A / 250 V AC. Load category/contact life not specified.
Optoisolated digital outputOpen collector; source maxima 30 V, 40 mA and 125 mW. Channel count not specified; combined ratings require confirmation.
Optoisolated PWMTwo outputs in feature list; open collector; source maxima 30 V, 40 mA, 125 mW; 0-1 kHz frequency, adjustable duty cycle. Electrical/frequency conditions Confirmation required.

Radio parameters

CM550-55 Series — Industrial RTU with GPS/BeiDou positioning · Source revision not stated · Source p. 5

CM550-55X — Radio parameters
Wireless moduleIndustrial wireless module; actual modem/configuration must be confirmed.
TDD radio groupLTE TDD 2600/2300 MHz; UMTS 2100/900 MHz; GSM 850/900/1800/1900 MHz; receive diversity UMTS 2100/900 MHz.
FDD radio groupLTE FDD 2600/2100/1800/DD800 MHz (source notation retained); UMTS 2100/900 MHz; receive diversity UMTS 2100/900 MHz.
Source encoding/mode listLTE/UMTS/HSPA+/HSDPA/HSUPA/WCDMA/EDGE/GSM.
TDD-group data ratesLTE TDD DL 68 Mbit/s / UL 17 Mbit/s; DC-HSPA+ DL 42 Mbit/s (category 24); HSPA+ DL 28 Mbit/s (category 18); HSDPA DL 14.4 Mbit/s (category 8); HSUPA+ 5.76 Mbit/s (category 6; source labels DL, direction Confirmation required); WCDMA CS UL/DL 64 kbit/s; WCDMA PS UL/DL 384 kbit/s.
FDD-group data ratesLTE FDD DL 100 Mbit/s / UL 50 Mbit/s; DC-HSPA+ DL 42 Mbit/s (category 24); HSPA+ DL 28 Mbit/s (category 18); HSDPA DL 14.4 Mbit/s (category 8); HSUPA+ 5.76 Mbit/s (category 6; source labels DL, direction Confirmation required); WCDMA CS UL/DL 64 kbit/s; WCDMA PS UL/DL 384 kbit/s.
Transmit powerLTE 23 dBm; WCDMA/HSDPA 24 dBm.
Receive sensitivity<-109 dBm.
servicesData, voice, SMS and fax; verify service support on the ordered modem and regional network.

Hardware and power

CM550-55 Series — Industrial RTU with GPS/BeiDou positioning · Source revision not stated · Source p. 6

CM550-55X — Hardware and power
CPU / MMUIndustrial CPU with MMU memory management.
Flash / SDRAM64 Mbit / 256 Mbit.
Input7-32 V DC in power table; 6-32 V in feature section. Confirm approved input.
Adapter9 V DC / 1.5 A
Communication current0.2 A at 9 V DC
Registration peak1.0 A at 9 V DC
Standby0.15 A at 9 V DC

Mechanical / environment

CM550-55 Series — Industrial RTU with GPS/BeiDou positioning · Source revision not stated · Source p. 6

CM550-55X — Mechanical / environment
HousingMetal, isolated enclosure/system, lightning/EMI design; IP30 .
Body167 x 104 x 26 mm excluding antennas/mounting.
Package350 x 215 x 88 mm
Weight0.52 kg
Operating-25 to +70 °C
Storage-40 to +85 °C
Humidity95% RH, non-condensing.

System connectivity

From field equipment to your system.

See how CM550-55X fits into your installation.

CM550-55X example data flowField equipment: Connected equipment. Serial equipment; RS232; Field sensors; Analog acquisition Next connection: Device data. Data acquisition: CM550-55X. Next connection: Project integration. Your system: Customer platform. Monitoring system or data server01 / FIELD EQUIPMENTConnected equipmentSerial equipmentRS232Field sensorsAnalog acquisitionDevice data02 / DATA ACQUISITIONCM550-55XCM550-55X product photographProject integration03 / YOUR SYSTEMCustomer platformMonitoring system or data serverCM550-55X example data flowField equipment: Connected equipment. Serial equipment; RS232; Field sensors; Analog acquisition Next connection: Device data. Data acquisition: CM550-55X. Next connection: Project integration. Your system: Customer platform. Monitoring system or data server01 / FIELD EQUIPMENTConnected equipmentSerial equipmentRS232Field sensorsAnalog acquisitionDevice data02 / DATA ACQUISITIONCM550-55XCM550-55X product photographProject integration03 / YOUR SYSTEMCustomer platformMonitoring system or data server

Illustrative connection architecture. External equipment and customer software are shown for context. Interfaces and options vary by configuration.

Downloads

CM550-55 Series — Industrial RTU with GPS/BeiDou positioning

Source revision not stated · Technical review edition · PDF

Download PDF

Discuss your project

Complete your project details, then select Email our team to open your email app. Review and send your inquiry there.

Interface, connectivity and customization requirements (optional)

* Required. Avoid confidential designs or sensitive personal information.