CM510-72X

Cellular serial data terminal

A cellular serial data terminal with RS485 and RS232 communications interfaces plus a separate RS232 debug port. The official software table lists MQTT and Modbus RTU/TCP conversion functions.

Serial interfaces
1 × RS485; 1 × RS232 communication port; 1 × RS232 debug port
Serial rate
300–115200 bit/s
DC input
7–32 V DC
Operating temperature
−30 to +75 °C
CM510-72X original product photograph, view 1

Product photography. Open full image ↗

Technical specifications

Options vary by model, hardware revision and firmware.

Key specifications

CM510-72X product specifications
Serial interfaces1 × RS485; 1 × RS232 communication port; 1 × RS232 debug port
Serial rate300–115200 bit/s
DC input7–32 V DC
Operating temperature−30 to +75 °C

Model selection

CM510-72X Series — Industrial cellular data transfer unit · Source v2.7 · Source p. 1

CM510-72X — Model selection
CM510-72FNetworks: 2G/3G/4G; RS232: Yes; RS485: Yes; Data buffer: 8k
CM510-72TNetworks: 4G/GSM; RS232: Yes; RS485: Yes; Data buffer: 8k
CM510-72FS-GCNetworks: 2G/3G/4G/5G; RS232: Yes; RS485: Yes; Data buffer: 8k

Connectivity and protocols

CM510-72X Series — Industrial cellular data transfer unit · Source v2.7 · Source pp. 5-6

CM510-72X — Connectivity and protocols
Access / authenticationAPN/VPDN; CHAP/PAP/MS-CHAP/MS-CHAPv2.
ProtocolsIP/ICMP/PPP, TCP/UDP, TCP Server and DNS. MQTT; Modbus RTU/TCP conversion; Ntrip Client/Server; HJ212-2005/2017.
Custom messagesCustom TCP/UDP registration and heartbeat packets; up to 4 centers.

Security, recovery and management

CM510-72X Series — Industrial cellular data transfer unit · Source v2.7 · Source pp. 5-6

CM510-72X — Security, recovery and management
User levelsAdministrator and maintenance user; secure login authentication.
Upgrade protectionDedicated secure upgrade mechanism, as described.
Link detectionPPP heartbeat, ICMP probing, TCP keepalive and application heartbeat; automatic reconnection. Continuous-online wording is a source claim.
WatchdogOperating self-check and fault self-recovery.
DialingPersistent connection or short connection; local-data/SMS/call activation and scheduled activation/disconnection.
ConfigurationLocal serial tool; RTool, SMS and CAIMORE forwarding-platform remote configuration.
BackupImport/export configuration files.
Upgrades / logsLocal serial or remote software upgrade; local/remote log output.
Optional platformsIndustrial cloud; Amazon AWS; Tencent Cloud; power cloud; Alibaba Cloud and other IoT platforms; CAIMORE forwarding platform; centralized management and batch configuration.

Interfaces

CM510-72X Series — Industrial cellular data transfer unit · Source v2.7 · Source pp. 6-7

CM510-72X — Interfaces
Serial8 data bits; 1/1.5/2 stop bits; none/odd/even parity; 300-115200 bit/s; no flow control. 1 RS485, 1 RS232 communication and 1 RS232 debug port.
I/O4 channels; digital input/output, SMS and network alarms.
EnableExternal control of device power.
IndicatorsData-transfer and online status.
AntennaSMA female, 50 ohm; optional 3/5/10/15 m extension leads.
SIM1.8/3/5 V push-type interface; 15 kV ESD protection.
Power connectorStandard three-pin locomotive-style socket.
OSReal-time operating system.

Cellular module

CM510-72X Series — Industrial cellular data transfer unit · Source v2.7 · Source pp. 6-7

CM510-72X — Cellular module
ModuleIndustrial low-power module; source lists FCC, CE, CCC and RoHS. Exact scope Confirmation required.
5GNR n1/n2/n3/n5/n7/n8/n20/n28/n41/n66/n71/n77/n78/n79; applies to 5G models.
LTE FDDB1/B3/B8
LTE TDDB38/B39/B40/B41
Legacy networksTD-SCDMA B34/B39; WCDMA B1; CDMA2000 1X/EVDO B5 (none of these on CM510-72T); GSM/GPRS/EDGE B3/B8.
Transmit power<24 dBm
Receiver sensitivity<-109 dBm

Power

CM510-72X Series — Industrial cellular data transfer unit · Source v2.7 · Source pp. 7-8

CM510-72X — Power
Input7-32 V DC with reverse-polarity, overvoltage and overcurrent protection.
Standard supply9 V DC / 1330 mA
Communication current60 mA at 12 V DC
Standby25 mA at 12 V DC

Physical/environment

CM510-72X Series — Industrial cellular data transfer unit · Source v2.7 · Source pp. 7-8

CM510-72X — Physical/environment
EnclosureMetal, shielding, isolated enclosure/system, lightning-protection design, power-safety requirements; IP41.
Body100 x 62 x 24 mm, excludes antennas/mounting; actual model takes precedence.
Package298 x 226 x 60 mm; actual model takes precedence.
Weight0.24 kg
Operating-30 to +75 °C
Storage-45 to +90 °C
Humidity95%, non-condensing.
Shock / vibration / dropIEC 60068-2-27 / IEC 60068-2-6 / IEC 60068-2-32.

EMC parameters

CM510-72X Series — Industrial cellular data transfer unit · Source v2.7 · Source pp. 7-8

Certification scope and test conditions depend on the selected model. Request the applicable documentation.

CM510-72X — Source-listed EMC parameters
ESDEN 61000-4-2, level 3
Radiated electric fieldEN 61000-4-3, level 3
Electrical fast transientEN 61000-4-4, level 3
SurgeEN 61000-4-5, level 3
Conducted disturbancesEN 61000-4-6, level 3
Power-frequency magnetic fieldEN 61000-4-8; horizontal/vertical 400 A/m (level 3), . Confirmation required.

product tests

CM510-72X Series — Industrial cellular data transfer unit · Source v2.7 · Source pp. 7-8

CM510-72X — Source-listed product tests
ClaimsChinese CCC; EMC testing; Mo'er high/low-temperature testing; environmental reliability report. No report IDs or model-specific certificate scope supplied.

System connectivity

From field equipment to your system.

See how CM510-72X fits into your installation.

CM510-72X example data flowField equipment: Connected equipment. Serial equipment; RS232 / RS485 Next connection: Device data. Serial data communication: CM510-72X. Next connection: Cellular network. Your system: Customer platform. Monitoring system or data server01 / FIELD EQUIPMENTConnected equipmentSerial equipmentRS232 / RS485Device data02 / SERIAL DATA COMMUNICATIONCM510-72XCM510-72X product photographCellular network03 / YOUR SYSTEMCustomer platformMonitoring system or data serverCM510-72X example data flowField equipment: Connected equipment. Serial equipment; RS232 / RS485 Next connection: Device data. Serial data communication: CM510-72X. Next connection: Cellular network. Your system: Customer platform. Monitoring system or data server01 / FIELD EQUIPMENTConnected equipmentSerial equipmentRS232 / RS485Device data02 / SERIAL DATA COMMUNICATIONCM510-72XCM510-72X product photographCellular network03 / YOUR SYSTEMCustomer platformMonitoring system or data server

Illustrative connection architecture. External equipment and customer software are shown for context. Interfaces and options vary by configuration.

Downloads

CM510-72X Series — Industrial cellular data transfer unit

Source v2.7 · Technical review edition · PDF

Download PDF

Discuss your project

Complete your project details, then select Email our team to open your email app. Review and send your inquiry there.

Interface, connectivity and customization requirements (optional)

* Required. Avoid confidential designs or sensitive personal information.