CM510-77T — Industrial cellular data transfer unit
Source V1.0 · Technical review edition · PDF
CM510-77T
A 4G cellular data terminal with an RS485 communications interface and a separate RS232 debug port. Its wide DC input range supports integration into powered equipment.

Product photography. Open full image ↗
Options vary by model, hardware revision and firmware.
| Serial interfaces | 1 × RS485 communication port; 1 × RS232 debug port |
|---|---|
| Serial rate | 300–115200 bit/s |
| DC input | 5–35 V DC |
| Operating temperature | −30 to +75 °C |
CM510-77T — Industrial cellular data transfer unit · Source V1.0 · Source p. 1
| CM510-77T | Network: 4G/GSM; RS232: Yes; RS485: Yes; Buffer: 8k |
|---|
CM510-77T — Industrial cellular data transfer unit · Source V1.0 · Source p. 4
| Serial | 8 data bits; 1/1.5/2 stop bits; none/odd/even parity; 300-115200 bit/s; no flow control. Detailed table lists one RS485 plus one RS232 debug port, unlike the general RS232/RS485 communication wording. Confirm actual port functions. |
|---|---|
| Enable | Customer control of power on/off, ; pin number not supplied. |
| Antenna | SMA female, 50 ohm; optional 3/5/10/15 m extension cables. |
| SIM | 1.8/3/5 V push-type card interface; 15 kV ESD protection. |
| Power connector | Standard 3-pin locomotive-style power socket, as described. Confirm actual connector with hardware. |
CM510-77T — Industrial cellular data transfer unit · Source V1.0 · Source p. 4
| Bands | LTE FDD B1/B3/B5/B8; LTE TDD B34/B38/B39/B40/B41; GSM 900/1800 MHz. |
|---|---|
| Transmit power | <24 dBm |
| Receive sensitivity | <-109 dBm |
CM510-77T — Industrial cellular data transfer unit · Source V1.0 · Source p. 5
| OS | Real-time OS. |
|---|---|
| Input | 5-35 V DC in technical table; 7-32 V in feature section. Confirmation required. |
| Adapter | 9 V DC / 1330 mA |
| Current | Communication 60 mA at 12 V; standby 25 mA at 12 V. |
| Body | 75 x 40 x 15 mm, excluding antenna and accessories. |
| Operating | -30 to +75 °C |
| Storage | -45 to +90 °C |
| Humidity | 95% RH, non-condensing. |
System connectivity
See how CM510-77T fits into your installation.
Illustrative connection architecture. External equipment and customer software are shown for context. Interfaces and options vary by configuration.
Source V1.0 · Technical review edition · PDF