CM510-81T

Compact LTE Cat 1 serial DTU

A compact cellular data terminal for RS232 and RS485 equipment, with TCP/UDP transfer, MQTT and Modbus RTU/TCP conversion. Match the regional cellular module and ordered firmware to the project.

Serial interfaces
1 × RS485 and 1 × RS232; 300–115200 bit/s
Cellular network
4G; confirm destination-country bands and carrier compatibility
Protocols
TCP/UDP, DNS, MQTT and Modbus RTU/TCP conversion; up to four centers listed
Configuration
Local serial configuration; RTool and CAIMORE forwarding-platform remote configuration listed
CM510-81T original product photograph, view 1

Product photography. Open full image ↗

Technical specifications

Options vary by model, hardware revision and firmware.

Key specifications

CM510-81T product specifications
Serial interfaces1 × RS485 and 1 × RS232; 300–115200 bit/s
Cellular network4G; confirm destination-country bands and carrier compatibility
ProtocolsTCP/UDP, DNS, MQTT and Modbus RTU/TCP conversion; up to four centers listed
ConfigurationLocal serial configuration; RTool and CAIMORE forwarding-platform remote configuration listed
Configuration backupImport and export of configuration files
LogsLocal or remote operating-log output listed
Body dimensions53.9 × 41.4 × 22.8 mm, excluding antenna and mounting hardware
Communication currentaverage: 30 mA at 9 V DC; operating and test conditions require confirmation

Confirm the approved input-voltage lower limit: the supplied PDF states 6–32 V in its power section and 7–32 V in its pin table. The official overview and specification table also differ on weight. Communication-current figures do not establish continuous-transmission power consumption. Firmware, regional bands and management-platform scope must be confirmed for the ordered configuration.

Model selection

CM510-81T — Industrial cellular data transfer unit · Source v1.2 · Source p. 1

CM510-81T — Model selection
CM510-81TNetworks: 4G; RS232: Yes; RS485: Yes; Data buffer: Not specified

Connectivity and protocols

CM510-81T — Industrial cellular data transfer unit · Source v1.2 · Source p. 5

CM510-81T — Connectivity and protocols
Access / authenticationAPN/VPDN; CHAP/PAP/MS-CHAP/MS-CHAPv2.
ProtocolsTCP/UDP and DNS; MQTT; Modbus RTU/TCP conversion.
Custom messagesCustom TCP/UDP registration and heartbeat packets; up to 4 centers.

Security, recovery and management

CM510-81T — Industrial cellular data transfer unit · Source v1.2 · Source p. 5

CM510-81T — Security, recovery and management
User levelsAdministrator and maintenance user; secure login authentication.
Upgrade protectionDedicated secure upgrade mechanism, as described.
Link detectionPPP heartbeat, ICMP probing, TCP keepalive and application heartbeat; automatic reconnection. Continuous-online wording is a source claim.
WatchdogOperating self-check and fault self-recovery.
ConfigurationLocal serial tool; RTool and CAIMORE forwarding-platform remote configuration.
BackupImport/export configuration files.
Upgrades / logsLocal serial or remote software upgrade; local/remote log output.
Optional platformsIndustrial cloud; Amazon AWS; Tencent Cloud; power cloud; Alibaba Cloud and other IoT platforms; CAIMORE forwarding platform; centralized management and batch configuration.

Interfaces

CM510-81T — Industrial cellular data transfer unit · Source v1.2 · Source p. 6

CM510-81T — Interfaces
Serial8 data bits; 1/1.5/2 stop bits; none/odd/even parity; 300-115200 bit/s; no flow control. 1 RS485 and 1 RS232 communication port.
OTGDiagnostic interface for fault investigation.
ResetQuick restart.
IndicatorsData-transfer and online status.
AntennaSMA female, 50 ohm; optional 3/5/10/15 m extension leads.
SIM1.8/3/5 V push-type interface; 15 kV ESD protection.
Power connectorIndustrial green terminal.
OSReal-time operating system.

Cellular module

CM510-81T — Industrial cellular data transfer unit · Source v1.2 · Source p. 6

CM510-81T — Cellular module
ModuleIndustrial low-power module; source lists FCC, CE, CCC and RoHS. Exact scope Confirmation required.
LTE FDDB1/B3/B5/B8
LTE TDDB34/B38/B39/B40/B41
Transmit power<24 dBm
Receiver sensitivity<-109 dBm

Power

CM510-81T — Industrial cellular data transfer unit · Source v1.2 · Source pp. 7-8

CM510-81T — Power
Input6-32 V DC with reverse-polarity, overvoltage and overcurrent protection.
Standard supply9 V DC / 1330 mA
Communication current30 mA at 9 V DC
Standby10 mA at 9 V DC

Physical/environment

CM510-81T — Industrial cellular data transfer unit · Source v1.2 · Source pp. 7-8

CM510-81T — Physical/environment
EnclosureMetal, shielding, isolated enclosure/system, lightning-protection design, power-safety requirements; IP41.
Body53.9 x 41.4 x 22.8 mm, excludes antennas/mounting; actual model takes precedence.
Package298 x 226 x 60 mm; actual model takes precedence.
Weight80 g
Operating-30 to +75 °C
Storage-45 to +90 °C
Humidity95%, non-condensing.
Shock / vibration / dropIEC 60068-2-27 / IEC 60068-2-6 / IEC 60068-2-32.

EMC parameters

CM510-81T — Industrial cellular data transfer unit · Source v1.2 · Source pp. 7-8

Certification scope and test conditions depend on the selected model. Request the applicable documentation.

CM510-81T — Source-listed EMC parameters
ESDEN 61000-4-2, level 3
Radiated electric fieldEN 61000-4-3, level 3
Electrical fast transientEN 61000-4-4, level 3
SurgeEN 61000-4-5, level 3
Conducted disturbancesEN 61000-4-6, level 3
Power-frequency magnetic fieldEN 61000-4-8; horizontal/vertical 400 A/m (level 3), . Confirmation required.

product tests

CM510-81T — Industrial cellular data transfer unit · Source v1.2 · Source pp. 7-8

CM510-81T — Source-listed product tests
ClaimsChinese CCC; EMC testing; Mo'er high/low-temperature testing; environmental reliability report. No report IDs or model-specific certificate scope supplied.

System connectivity

From field equipment to your system.

See how CM510-81T fits into your installation.

CM510-81T example data flowField equipment: Connected equipment. Serial equipment; RS232 / RS485 Next connection: Device data. Serial data communication: CM510-81T. MQTT · Modbus Next connection: Cellular network. Your system: Customer platform. Monitoring system or data server01 / FIELD EQUIPMENTConnected equipmentSerial equipmentRS232 / RS485Device data02 / SERIAL DATA COMMUNICATIONCM510-81TCM510-81T product photographMQTT · ModbusCellular network03 / YOUR SYSTEMCustomer platformMonitoring system or data serverCM510-81T example data flowField equipment: Connected equipment. Serial equipment; RS232 / RS485 Next connection: Device data. Serial data communication: CM510-81T. MQTT · Modbus Next connection: Cellular network. Your system: Customer platform. Monitoring system or data server01 / FIELD EQUIPMENTConnected equipmentSerial equipmentRS232 / RS485Device data02 / SERIAL DATA COMMUNICATIONCM510-81TCM510-81T product photographMQTT · ModbusCellular network03 / YOUR SYSTEMCustomer platformMonitoring system or data server

Illustrative connection architecture. External equipment and customer software are shown for context. Interfaces and options vary by configuration.

Downloads

CM510-81T — Industrial cellular data transfer unit

Source v1.2 · Technical review edition · PDF

Download PDF

Discuss your project

Complete your project details, then select Email our team to open your email app. Review and send your inquiry there.

Interface, connectivity and customization requirements (optional)

* Required. Avoid confidential designs or sensitive personal information.